PIC/S ANEKS 1 (PEMBUATAN PRODUK STERIL) – PENGAWASAN MUTU NO VERSI ASLI VERSI TERJEMAHAN 125 The sterility test applied to the finished product should only be regarded as the last in a series of control measures by which sterility is assured. The test should be validated…

PIC/S ANEKS 1 (PEMBUATAN PRODUK STERIL) – STERILISASI CARA RADIASI

PIC/S ANEKS 1 (PEMBUATAN PRODUK STERIL) – STERILISASI CARA RADIASI NO VERSI ASLI VERSI TERJEMAHAN 98 Radiation sterilisation is used mainly for the sterilisation of heat sensitive materials and products. Many medicinal products and some packaging materials are radiation-sensitive, so this method is permissible only when…

PIC/S ANEKS 1 (PEMBUATAN PRODUK STERIL) – STERILISASI CARA PANAS BASAH

PIC/S ANEKS 1 (PEMBUATAN PRODUK STERIL) – STERILISASI CARA PANAS BASAH NO VERSI ASLI VERSI TERJEMAHAN 94 Both temperature and pressure should be used to monitor the process. Control instrumentation should normally be independent of monitoring instrumentation and recording charts. Where automated control and monitoring systems…

PIC/S ANEKS 1 (PEMBUATAN PRODUK STERIL) – STERILISASI CARA PANAS

PIC/S ANEKS 1 (PEMBUATAN PRODUK STERIL) – STERILISASI CARA PANAS NO VERSI ASLI VERSI TERJEMAHAN 90 Each heat sterilisation cycle should be recorded on a time/temperature chart with a sufficiently large scale or by other appropriate equipment with suitable accuracy and precision. The position of the…